- Metal Building Materials[4]
- Terminal Blocks[1]
- Other Electrical Equipment[1]
- Electrical Wires[10]
- Instrumentation Cables[10]
- Other Wires[4]
- Wiring Harness[1]
- Sensors[1]
- Resistors[1]
- Electric Heater Parts[3]
- Other Home Appliance Parts[1]
- Industrial Heater[10]
- Refrigeration & Heat Exchange Parts[3]
- Other Electronic Measuring Instruments[2]
- Flow Meters[1]
- Instrument Parts & Accessories[5]
- Other Measuring & Analysing Instruments[5]
- Pressure Gauges[10]
- Temperature Instruments[10]
- Flanges[1]
- Aluminum Wire[2]
- Other Graphite Products[1]
- Stainless Steel Bars[3]
- Stainless Steel Pipes[2]
- Stainless Steel Strips[1]
- Steel Pipes[3]
- Contact Person : Ms. Yuan April
- Company Name : Jiangsu Plaza Premium Electric Instrument Co., Ltd.
- Tel : 086-0523-86155311
- Fax : 086-0523-83767111
- Address : Jiangsu,taizhou,Zhangguo Town Industrial Zone
- Country/Region : China
- Zip : 225722
Related Product Searches:thermocouple,RTD,sensor,High Quality,Thermocouple, pt100 rtd sensor,WR
Application It is usually connected with display meter, recording meter and computer, etc. to directly measure temperature of liquid, vapor, gas and solid surface ranging from 0°C to 1300°C during various production process.Features1.With quick response, reducing dynamic error;
2.Optional installation methods;
3.Wide measuring range ;4.High mechanical strength, good pressure-resistant performanceOperation theoryThe electrodes of armored thermocouple are made of two different materials. the temperature difference between measuring end and reference end results in pyroelectric potential ,then the meter indicates the corresponding temperature to the pyroelectic potential.Mail technical parametersExecutive standard:IEC584IEC1515GB/T16839-1997JB/T5582-91
RTD Measuring range & Tolerance
Type | Graduation | Tolerance class | |||||
I | II | ||||||
Tolerance value | Measuring range°C | Tolerance value | Measuring range°C | ||||
WRNK | K | ±1.5°C | -40~+375 | ±2.5°C | -40~+333 | ||
±0.004|t| | 375~1000 | ±0.0075|t| | 333~1200 | ||||
WRMK | N | ±1.5°C | -40~+375 | ±2.5°C | -40~+333 | ||
±0.004|t| | 375~1000 | ±0.0075|t| | 333~1200 | ||||
WREK | E | ±1.5°C | -40~+375 | ±1.5°C | -40~+333 | ||
±0.004|t| | 375~800 | ±0.004|t| | 333~900 | ||||
WRFK | J | ±1.5°C | -40~+375 | ±1.5°C | -40~+333 | ||
±0.004|t| | 375~750 | ±0.004|t| | 333~750 | ||||
WRCK | T | ±1.5°C | -40~+125 | ±1°C | -40~+133 | ||
±0.004|t| | 125~350 | ±0.0075|t| | 133~1000 | ||||
WRPK | S | ±1°C | 0~+1100 | ±2.5°C | 0~600 | ||
±[0.003(t-1100)] | 1100~1600 | ±0.0025|t| | 600~1600 |